Simple-to-use fiber-loss tester with advanced time-saving features. Choose from various kits with configurations to meet your fiber verification, inspection, and cleaning needs.
Today’s high-bandwidth premises networks depend on a reliable fiber optic infrastructure. Proper installation and maintenance of fiber cabling is imperative for minimizing network downtime. Whether you require basic fiber verification capabilities, advanced troubleshooting and inspection, or documented loss and power measurements, Fluke Networks’ SimpliFiber® Pro Optical Power Meter and Fiber Test Kits are the best first-line fiber instruments to meet your needs.
SimpliFiber® Pro Optical Power Meter and Fiber Test Kits include all the tools necessary to verify and troubleshoot optical fiber cabling systems, measure loss and power levels, and inspect and clean connector end-faces. Replacing the popular SimpliFiber series, these next generation optical loss test kits boast industry-leading functions such as dual-wavelength testing and automatic-wavelength detection, in addition to unique features such as CheckActive™, FindFiber™, and Min/Max. With such advanced, yet easy-to-use, capabilities that reduce test times, SimpliFiber Pro is simply the best first-line fiber test kit on the market.
Whether you require basic fiber verification capabilities, advanced cable troubleshooting and inspection, or documented loss and power measurements, Fluke Networks’ SimpliFiber Pro® Optical Loss Test Kits provide you with the rugged, high quality tools that meet your fiber testing needs.
Complete Fiber Verification Kit (FTK1450)
The Complete Fiber Verification Kit is for contractors and network technicians who install and maintain premises networks with both multimode and singlemode optical fiber. Use this kit to verify optical loss and power levels at 850, 1300, 1310, 1490, 1550, and 1625 nm, inspect fiber end-faces, locate cable faults, connector problems, and polarity issues. Kit combinations offer a variety of inspection options.
Full-Featured Inspection and Multimode Verification Kits (FTK1300 and FTK1350)
The Full-Featured Inspection and Multimode Verification Kits are for contractors and network technicians who install and maintain multimode premises networks. Use these kits to verify optical loss and power levels at 850 and 1300 nm, inspect fiber end-faces, locate cable faults, connector problems, and polarity issues. Kit combinations offer a variety of inspection options.
Basic Verification Kits (FTK1000-MM and FTK2000-SM)
The Basic Verification Kits are great starter kits for contractors and network technicians who install and maintain fiber links. Available in singlemode or multimode configurations, quickly verify optical loss and power levels at 850 and 1300 nm or 1310 and 1550 nm. Add additional sources, microscopes, and VFL options as needed.
Copper and Fiber Technician's Kit (CIQ-FTKSFP)
Consisting of the CableIQ (CIQ-KIT) and the SimpliFiber Pro Basic Verification Kit (FTK1000), Fluke Networks' Copper and Fiber Technician's Kit provides a robust combination of tools to help you expertly manage your network to it keep it running smoothly and inexpensively. Simple-to-use straight from the box, you can do everything from quickly troubleshooting and qualifying cabling link bandwidth to verifying optical fiber power and loss.
Ensure accurate and consistent measurements when testing multimode fiber.
Fluke Networks offers multimode fiber mandrels that provide a foolproof, cost-effective method of improving the repeatability and consistency of multimode optical power and loss measurements when using an LED source. Our mandrels guarantee the correct number of wraps of the appropriate diameter as specified by the TIA/EIA-568-B standard while protecting 3 mm fiber cables from damage and preventing unwanted microbends.
Fluke Networks’ Multimode Fiber Mandrels offer a simple, cost effective way to:
Fluke Networks' Multimode Fiber Mandrels feature groves that enable the user to wrap the cable from the source five times around the mandrel. A retainer keeps the cable in place while not adversely pinching the fiber - making its use foolproof. The fiber mandrels are sized for 3 mm fiber cables - the most commonly used patch cable type in the industry. A 22 mm mandrel is available for 50/125 µm fiber and a 17 mm mandrel is available for 62.5/125 µm fiber.
Ensure smooth, clean fiber connections.
With a range of solutions, Fluke Networks has the right tool to easily inspect end-faces on a wide variety of connectors.
FT120 and FT140 FiberViewers are handheld microscopes used to inspect the end-faces of fiber-optic connectors. The microscopes ensure your termination is smooth, clean, and ready for optical transmission. The Fluke Networks FT120 200x FiberViewer is used to inspect multimode fiber end-faces. For singlemode installation, Fluke Networks offers the FT140 FiberViewer with 400X magnification. Both microscopes contain a special safety filter to protect your eyes from harmful infrared rays.

FT500 FiberInspector Mini is a convenient video microscope; it enables end-face inspection of inside ports and fiber optic connectors. Simply insert the probe and inspect installed fiber connectors through the bulkhead adapters without accessing the backside of the patch panels.
An important addition to your verification, troubleshooting, and inspection tasks is fiber cleaning. Dirt, dust, and other contaminants are the enemy of high-speed data transmission over optical fiber. Today's network applications require more bandwidth, making loss budgets tighter than ever. It is critical that all optical connections are clean and free of contaminants to ensure application success.
Fluke Networks’ Fiber Optic Cleaning Kits have the best tools to effectively remove the toughest contaminants with ease.
FT525 Fiber Cleaning and Inspection Kit
FiberInspector Mini and Cleaning Kit – Includes FiberInspector Mini; complete cleaning supplies (cleaning cube, ten cleaning cards, solvent pen, 2.5 mm port cleaning swabs and 1.25 mm port cleaning swabs) and soft carrying case.
NFC-KIT-BOX
Fiber Optic Cleaning Kit includes cleaning cube with wipes, five cards with sealed cleaning zones, solvent pen and 2.5mm port cleaning swabs.
NFC-KIT-CASE
Fiber Optic Cleaning Kit includes cleaning cube with wipes, ten cards with sealed cleaning zones, solvent pen, 2.5 mm port cleaning swabs and 1.25 mm port cleaning swabs in a rugged carrying case.
Manage fiber test results with LinkWare Cable Test Management Software.
Fluke Networks' powerful LinkWare software helps you quickly organize, edit, view, print, save, or archive test results by job site, customer, campus building, and more. You can merge test results into an existing database and then sort, search, and organize by any number of data fields or parameters.
LinkWare is available free from our web site. As a contractor, once your work is done, you can give this powerful application to your customer so they can have instant access to the data electronically or you can export the data as an Adobe Portable Document Format (PDF).
Extensive data management capabilities with LinkWare:
LinkWare prints professional, graphical reports with color graphs depicting the measured test parameters. You can choose which parameters to print and the order in which graphs appear. Reports can also be customized with your company logo.
LinkWare Stats provides a graphical analysis of your entire cable plant
LinkWare now supports LinkWare Stats, an automated statistical report option that allows you to move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare cable test data into graphics that reveal your cabling plant performance-summarizing your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and spot anomalies.
See what LinkWare Stats can do with your data - a free demo version of LinkWare Stats is included with every copy of LinkWare.
The laser-powered VisiFault™ Visual Fault Locator verifies continuity and polarity, and helps find breaks and bends in cables, and locate problems in connectors and splices. VisiFault emits a bright beam of red light easily visible from a distance. Connect the VisiFault to one end of a fiber - then locate that fiber at the other end, even if it is one of many fibers either in a cable or terminated in a rack. Perform simple end-to-end continuity checks.
VisiFault can quickly illuminate fiber breaks, damaged connectors on patch cords, defective splices in splice trays, and tight fiber bends in and around equipment racks. The choice of a continuous wave output mode for steady fault illumination or a flashing output mode makes for easier fault location.
The integrated universal 2.5 mm adapter makes for easy connection to SC, ST, FC, and FJ connectors. The optional 1.25 mm adapter allows for connection to LC and MU connectors. Attach the VisiFault to your belt using a lanyard or in the carrying case so it is always on hand when you need it. Long battery life for hours of use, includes two AA batteries giving you more than 80 hours of continuous mode battery life.
Fluke Networks built the VisiFault to last.
VisiFault incorporates an energy-absorbing holster over an impact-resistant case to withstand drops, impacts and rough treatment. Together with a heavy-duty tethered end cap to protect the fiber adapter, VisiFault is the VFL for demanding field applications. Unlike more fragile VFLs that utilize a flashlight body or plain plastic case, Fluke Networks engineered the VisiFault custom-case to be compact, ergonomic and mechanically tough for field use.

Time-saving capabilities such as CheckActive™, FindFiber™, and Min/Max make SimpliFiber Pro the best fiber test kit on the market.
CheckActive™
What is it? The SimpliFiber Pro power meter emits an audible tone and displays an icon when a live link or port is detected.
How will it save time? This feature provides quick confirmation of whether a link or port is live. No power measurement set up is required.

FindFiber™
What is it? Identifies cabling runs and ensures polarity.
How will it save time? This feature provides fast cable-routing identification with just one technician, enabling easy cable-mapping verification and documentation.

Min/Max
What is it? Tracks a testing session’s power fluctuations.
How will it save time? This feature accurately identifies intermittent power fluctuations and eliminates unreliable and inaccurate guesswork. It also eliminates the need for constant monitoring due to the auto-pilot tracking feature.

| Model Number/Name | Description |
| SFSINGLEMODE2 | SimpliFiber Pro singlemode 1490/1625 laser light source. Fixed SC port (with ST and LC testing capability available using hybrid test-reference cord accessories purchased separately). Includes FindFiberTM source capability. |
| SFPOWERMETER | SimpliFiber Pro optical power meter; SC adapter included. See Photo |
| SFMULTIMODESOURCE | SimpliFiber Pro multimode 850/1300 light source. Fixed SC port (with ST and LC testing capability available using hybrid test-reference cord accessories purchased separately). Includes FindFiberTM source capability. |
| SFSINGLEMODESOURCE | SimpliFiber Pro singlemode 1310/1550 laser light source. Fixed SC port (with ST and LC testing capability available using hybrid test-reference cord accessories purchased separately). Includes FindFiberTM source capability. |
| Model Number/Name | Description |
| FTK2100 | Singlemode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, two singlemode sources (1310/1550 and 1490/1625 nm), carrying case, and SC power-meter adapter. |
| CIQ-FTKSFP | Copper and Fiber Technician’s Kit – Includes the CableIQ (CIQ-KIT) and SimpliFiber Pro (FTK1000) Fiber Test Kit. See Photo |
| MS2-FTK | Copper and Fiber Basic Technician’s Kit – Includes the MicroScanner (MS2-100) and SimpliFiber Pro (FTK1000) Fiber Test Kit. |
| FTK1450 | Complete Fiber Verification Kit with FT500 FiberInspector Mini – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, 1310/1550 singlemode source, VisiFault VFL, FT500 FiberInspector Mini, two (2) FindFiber Remote ID sources, and carrying case; SC, ST, and LC power meter adapters, NFC-KIT-BOX fiber optic cleaning kit. See Photo |
| FTK1350 | Multimode Fiber Verification Kit with FT500 FiberInspector Mini – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, VisiFault VFL, FT500 FiberInspector Mini, FindFiber Remote ID source, and carrying case; SC, ST, and LC power meter adapters. See Photo |
| FTK1300 | Multimode Fiber Verification Kit with FT120 FiberViewer – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, VisiFault VFL, FT120 FiberViewer, FindFiber Remote ID source, and carrying case; SC, ST, and LC power meter adapters. See Photo |
| FTK1000 | Multimode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, carrying case, and SC power-meter adapter. See Photo |
| FTK2000 | Singlemode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, 1310/1550 singlemode source, carrying case, and SC power-meter adapter. See Photo |
| Model Number/Name | Description |
| NFK1-EFLC-SC | One 62.5 µm SC/SC Encircled Flux Launch Controller (two required for DTX) |
| NFK1-EFLC-LC | One 62.5 µm SC/LC Encircled Flux Launch Controller (two required for DTX) |
| NFK2-EFLC-SC | One 50 µm SC/SC Encircled Flux Launch Controller (two required for DTX) |
| NFK2-EFLC-LC | One 50 µm SC/LC Encircled Flux Launch Controller (two required for DTX) |
| FINDFIBER | One (1) FindFiber Remote ID source. See Photo |
| FINDFIBER-6 | Set of six (6) FindFiber Remote ID sources |
| FT500 | FiberInspector Mini Video Microscope - Includes fiber probe and display, AC adapter/battery charger, probe adapter tips (ST, SC and universal 2.5mm patch cord tip) and soft carrying case). See Photo |
| FT525 | FiberInspector Mini and Cleaning Kit – Includes FiberInspector Mini; complete cleaning supplies (cleaning cube, ten cleaning cards, solvent pen, 2.5mm port cleaning swabs and 1.25mm port cleaning swabs) and soft carrying case. See Photo |
| FT120 | Fiber Viewer - 200X magnification with 2.5mm Universal Adapter |
| FT140 | Fiber Viewer - 400X magnification with 2.5mm Universal Adapter |
| NFC-Kit-Box | Fiber Optic Cleaning Kit - Includes cleaning cube with wipes, five cards with sealed cleaning zones, solvent pen and 2.5mm port cleaning swabs |
| NFC-Kit-Case | Fiber Optic Cleaning Kit - Includes cleaning cube with wipes, ten cards with sealed cleaning zones, solvent pen, 2.5mm port cleaning swabs and 1.25mm port cleaning swabs in a rugged carrying case. See Photo |
| NFK1-SMPLX-SC | 62.5 uM simplex test-reference cord set (SC/SC x 2); special patented damage-resistant end-faces |
| NFK1-SMPLX-LC | 62.5 uM simplex test-reference cord set (SC/LC, LC/LC); special patented damage-resistant end-faces |
| NFK1-SMPLX-ST | 62.5 uM simplex test-reference cord set (SC/ST, ST/ST); special patented damage-resistant end-faces |
| NFK2-SMPLX-SC | 50 uM simplex test-reference cord set (SC/SC x 2); special patented damage-resistant end-faces |
| NFK2-SMPLX-LC | 50 uM simplex test-reference cord set (SC/LC, LC/LC); special patented damage-resistant end-faces |
| NFK2-SMPLX-ST | 50 uM simplex test-reference cord set (SC/ST, ST/ST); special patented damage-resistant end-faces |
| NFK3-SMPLX-SC | Singlemode test-reference cord set (SC/SC x 2); special patented damage-resistance end-faces |
| NFK3-SMPLX-LC | Singlemode test-reference cord set (SC/LC, LC/LC); special patented damage-resistance end-faces |
| NFK3-SMPLX-ST | Singlemode test-reference cord set (SC/ST, ST/ST); special patented damage-resistance end-faces |
| NFM110 | Accessory Tip Set for FiberInspector Mini (LC, FC and 1.25mm Universal) See Photo |
| NFM115 | Complete Accessory Tip Set for FiberInspector Mini (Replacement SC, ST, and 2.5 Universal tips along with additional LC, FC, and 1.25mm Universal) See Photo |
| NFA-SC-SINGLE | SC interchangeable adapter |
| NFA-LC-SINGLE | LC interchangeable adapter |
| NFA-ST-SINGLE | ST interchangeable adapter |
| NFA-FC-SINGLE | FC Interchangeable Adapter |
| Model Number/Name | Description |
| GLD-SFPro | 1-Year Gold Support coverage for the SimpliFiber Pro devices and test kits: Models - SFPOWERMETER, FTK1000 and FTK2000 |
| GLD-FTK | 1-Year Gold Maintenance Support for SimpliFiber Pro Fiber Test Kits - Models: FTK1300, FTK1350, FTK1450, and FTK2100 |
| Environmental Specifications | |
| Operating Temperature | -10º C to 50º C |
| Storage Temperature | -20º C to 50º C |
| Operating Humidity |
|
| EMI, RFI, EMC | Standards compliant1 |
| Optical Power Meter | |
| Detector Type | InGaAs |
| Calibrated Wavelengths | 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm |
| Measurement Range |
|
| Power Measurement Linearity |
|
| Power Measurement Uncertainty3 | ±0.25 dB |
| Display Resolution, dB or dBm | 0.01 dB |
| Auto Dual-Wavelength Switching | Yes |
| Power Display Units | dBm, mW, μW |
| Auto-Wavelength Detection | Yes |
| Data Storage | 1000 records, multiple wavelengths per record |
| External Interface | USB, 2.0 full speed |
| Optical Connector | Removable adapter, SC adapter as default, optional adapters include LC, ST |
| Display update rate | 1 reading per second |
| Reference | Individually set for each wavelength |
| FindFiber ID detection | Yes |
| Power Requirement | 2 AA Alkaline batteries |
| Battery Life4 | > 50 Hours (typical) |
| Automatic Power Off | 10, 20, 30 or 60 minutes (can be disabled by user) |
| Low Battery Warning | Yes, low battery icon blinks |
| Size (L x W x H) | 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm) |
| Weight | 11.5 oz (325 grams) |
| Multimode Optical Source | |
| Emitter Type | LED |
| Central Wavelength | 850 nm, 1300 nm |
| Wavelength Accuracy |
|
| Spectral Width (FWHM) |
|
| Minimum Output Power | 850/1300 nm: ³ -20 dBm |
| Power Output Stability1 | ±0.1 dB over 8 hours |
| Auto Dual-Wavelength Switching | Yes. Can be enabled/disabled by user. |
| Optical Output Connector | Fixed SC |
| FindFiber Code Generation | Yes. Fixed at ID 1. |
| Modes | CW, 2 kHz modulated, Auto-wavelength |
| Power Requirement | 2 AA Alkaline batteries. |
| Battery Life2 | 40 hrs (typical) |
| Automatic Power Off | 30 minutes (can be disabled by user) |
| Low Battery Warning | Yes, LED blinks |
| Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
| Weight | 1.8 oz (278 g) |
| Singlemode Optical Source | |
| Emitter Type | 1310 nm/1550 nm: dual FP laser 1490 nm/1625 nm: dual DFB laser |
| Central wavelength |
|
| Wavelength Accuracy |
|
| Spectral width (RMS) |
|
| Minimum output power | 1310/1550 nm ≥ -7dBm (typical) 1490 nm/1625 nm: ≥ -3 dBm (typical) |
| Power Output Stability1 | ±0.25 dB over 8 hours |
| Auto Dual-Wavelength Switching | Yes. Can be enabled or disabled by user. |
| Optical Connector | Fixed SC |
| Launch Condition | 9/125 μm fiber |
| FindFiber Code Generation | 1310/1550 source is fixed at ID 2 1490 nm/1625 nm is fixed at ID 3. |
| Modes | CW, 2 kHz modulated, Auto-wavelength |
| Power Requirement | 2 AA Alkaline batteries |
| Battery Life2 | 30 hrs (typical) |
| Automatic Power Off | 30 minutes (can be enabled or disabled by user) |
| Low Battery Warning | LED blinks. |
| Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
| Weight | 9.8 oz (278 grams) |
| FindFiber Source Specifications | |
| Emitter Type | Laser |
| Source Connector | Fixed SC |
| FindFiber Code Generation | 1 through 8. Default is 3. |
| Power On/Low-battery Indicator | LED |
| Power Requirement | 2 AA Alkaline batteries |
| Battery Life | > 80 Hours (typical) |
| Automatic Power Off | 30 minutes |
| Low Battery Warning | LED blinks |
| Size (L x W x H) | 7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm) |
| Weight | 4.4 oz (125 g) |
| Safety | Meets Class 1 CDRH |
| Title/Description | Download | |
Fiber Troubleshooting Quick-Reference Guide
Optical Fiber Cabling for Data Communication – Test and Troubleshooting Quick-Reference Guide | Download PDF (5.27 MB) | |
Industrial Networks Troubleshooting Guide
Troubleshooting Guide for Industrial Ethernet and Other Network Protocols | Download PDF (6.61 MB) |
| Title/Description | Download | |
Copper and Fiber Network Troubleshooting Kit Data Sheet: LinkRunner Duo And SimpliFiber Pro
Copper and Fiber Network Troubleshooting Kit Data Sheet: LinkRunner Duo And SimpliFiber Pro | Download PDF (483 KB) | |
SimpliFiber Pro Multimode and Singlemode Sources Specifications
SimpliFiber Pro Multimode and Singlemode Sources Specifications | Download PDF (333 KB) | |
Simplifiber Pro Optical Power Meter And Fiber Test Kits Datasheet
Simplifiber Pro Optical Power Meter And Fiber Test Kits Datasheet | Download PDF (3.5 MB) | |
Copper and Fiber Basic Technicians Kit Data Sheet: MicroScanner2 And SimpliFiber Pro
Copper and Fiber Basic Technicians Kit Data Sheet: MicroScanner2 And SimpliFiber Pro | Download PDF (516 KB) | |
Copper And Fiber Technician's Kit
CableIQ and SimpliFiber Pro Kit | Download PDF (647 KB) | |
FindFiber Remote ID Source spec sheet
FindFiber Remote ID Source spec sheet | Download PDF (2.33 MB) |
| Title/Description | Download | |
Fluke Networks' Solution Catalog
64 page guide to selection and ordering Fluke Networks' Solutions and Products | Download PDF (6.39 MB) |
| Title/Description | Download | |
Encircled Flux Application Note
How will Encircled Flux launch conditions improve my link loss measurements? | Download PDF (1.13 MB) | |
Application Note: How to Choose the Right Power Meter Light Source
Top 4 Questions to Ask a Power Meter Light Source Vendor | Download PDF (532 KB) |
| Title/Description | Download | |
Fiber Test Best Practices: Tier 1 Certification
Fiber Test Best Practices: Tier 1 Certification | Download PDF (194 KB) |
| Title/Description | Download | |
Fiber Instruments Comparison Guide
Side-by-side comparison of the fiber tools you need for inspection and cleaning, loss-length certification, and fiber plant characteriziation and troubleshooting. | Download PDF (394 KB) |